orange issc logo
Quick Selector Guides

| Motion Detectors | Resistance Detectors | PLC Watchdog Timers |

Selecting a 'Type' link will show an operational description and timing diagram.
The links in the 'Model' column will take you to a detailed description of that model.

Available now in PDF format
updated 9/2002, file size 39k
If you don't already have a way to view PDF files Get Acrobat Reader


Timer Quick Selector Guide

Type 1 On Delay
Time Range Base Plug-in Block Panel Input Output Model

0.06-500 secs.

X




AC

R/SS(1)

1010

X




AC

R

1013

X




AC

R(3)

1014

0.025-10 secs.

X




AC/DC

R

1017(4)

0.02-500 secs.

X




AC/DC

R

1019

0.025-2000 secs.(2)


X



AC/DC

R

1071

0.1-10230 sec.



X


AC/DC

SS

2110

0.1 sec.-1000 min.



X


AC/DC

SS

2112

0.02-100 hrs.(2)


X


X

AC/DC

R

1073

Type 2 Off Delay
Time Range Base Plug-in Block Panel Input Output Model

0.06-500 secs

X




AC

R/SS(1)

1010

X




AC

R

1013

X




AC

R(3)

1014

0.06-1000 secs

X




AC/DC

R

1018

0.02-500 secs


X


X

AC/DC

R

1081

Type 3 Programmable
Time Range Base Plug-in Block Panel Input Output Model

0.1secs.-500 hr. (7)





AC/DC

R (3)

1055

0.02 sec-100 hrs


X


X

AC/DC

R

1090

0.01 sec-9,999 hrs


X


X

AC/DC

R/SS

1094

0.01 sec-9,999 hrs


X


X

AC/DC

R/SS

1095

0.01 sec-9,999 hrs(6)


X


X

AC/DC

R/SS

1096

Counter


X


X

AC/DC

R/SS

1105C

Types 4 & 5 Pulsed & Maintained Interval
Time Range Base Plug-in Block Panel Input Output Model

0.06-500 secs.

X




AC

R/SS(1)

1010

X




AC

R

1013

0.06-1000 secs.

X




AC/DC

R

1018

Type 5 Maintained Interval
Time Range Base Plug-in Block Panel Input Output Model

0.1-10230 secs



X


AC

SS

2115

Types 6, 7 & 8 Pulsed & Maintained On-Off One Cycle, On Delay/Off Delay
Time Range Base Plug-in Block Panel Input Output Model

0.06-500 secs

X




AC

R/SS

1030

Type 9 Repeat Cycle
Time Range Base Plug-in Block Panel Input Output Model

0.06-500 secs

X




AC

R/SS

1060

X




AC

SS

1061

0.02 sec-100 hr(2)


X


X

AC/DC

R

1068

1.5-15 sec. "ON" / 1-60 min. "OFF"



X


AC/DC

SS

2120

Motion Detector Quick Selector Guide

Sensor Application

Adjustment Range Operating Speed Mechanical Input Prox Input Model

Zero Speed

0.06-100 secs

1,080 ppm

X


1214

5-5000 ppm

12,000 ppm

Self contained

1248A

0.06-500 secs

2,400 ppm

X

X

1260

0.02-1000 secs

108,000 ppm

X

X

1262

Underspeed

5-5000 ppm

12,000 ppm

Self contained

1248A

0.02-1000 secs

108,000 ppm

X

X

1262

0.06-100 secs

1080 ppm


X

1217

Overspeed

5-5000 ppm

12,000 ppm

Self contained

1248A

0.02-1000 secs

108,000 ppm

X

X

1262

Resistive Sensitive Switch Selector Guide

Type Base Mount Plug-in Input Output Model

Standard switch

X


AC

R

1213


X

AC

SS

1230

Built-in timer
0.05-1 sec.

X


AC/DC

R

1232

Range detector

X


AC/DC

R

1234

Liquid level
detector

X


AC

SS

LLD-100

PLC Watchdog Selector Guide

Adjustment Range

Power supply

Output

Model

0.06-500 secs

120 VAC

Relay

1260

0.06-100 secs

120 VAC 24VAC/DC

Relay

1217

0.02-1000 secs

120 VAC

Relay

1262


Notes:
(1) R=relay SS=solid state R/SS=relay standard, solid state optional.
(2) Programmable time ranges.
(3) Timed and instant contacts.
(4) Special version available for electric utility industry.
(5) Non-volatile, retains count when power is removed.
(6) Two adjustable time periods. (7) Rail mounting.


| ISSC/Kanson Electronics Home | ISSC Products |
| What's New | Feature Products | Timers | Block timers | DIN style timers | Resistive Sensitive Switches | Motion Detectors/PLC Watchdogs | Accessories |
| Selector Guide | Factory Stock List | Functions | PDF data sheet index | Distributors |